NEW Browse AI tools across categories — updated daily. See what's new →
★ Featured Testing & Quality

Mdr 745 Specialist

EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/I...

Version1.0.0
LicenseMIT
Token count~2,448
UpdatedJun 4, 2026

EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/III technical files, Annex XIV clinical evaluation, and EUDAMED integration.

Install

Quick install

via npx skills · works with 57+ agents
npx skills add https://github.com/alirezarezvani/claude-skills/tree/main/ra-qm-team/skills/mdr-745-specialist
Or pick agent:
npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist --agent claude-code
npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist --agent cursor
npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist --agent codex
npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist --agent opencode
npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist --agent github-copilot
npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist --agent windsurf
More install options

Shorthand — useful for multi-skill repos:

npx skills add alirezarezvani/claude-skills --skill mdr-745-specialist

Manual — clone the repo and drop the folder into your agent's skills directory:

git clone https://github.com/alirezarezvani/claude-skills.git
cp -r claude-skills/ra-qm-team/skills/mdr-745-specialist ~/.claude/skills/
How to use: Once installed, ask your agent to "use the mdr-745-specialist skill" or describe what you want (e.g. "EU MDR 2017/745 compliance specialist for medical device classification, technic"). Requires Node.js 18+.

MDR 2017/745 Specialist

EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence.

---

Table of Contents

  • [Device Classification Workflow](#device-classification-workflow)
  • [Technical Documentation](#technical-documentation)
  • [Clinical Evidence](#clinical-evidence)
  • [Post-Market Surveillance](#post-market-surveillance)
  • [EUDAMED and UDI](#eudamed-and-udi)
  • [Reference Documentation](#reference-documentation)
  • [Tools](#tools)

---

Device Classification Workflow

Classify device under MDR Annex VIII:

  1. Identify device duration (transient, short-term, long-term)
  2. Determine invasiveness level (non-invasive, body orifice, surgical)
  3. Assess body system contact (CNS, cardiac, other)
  4. Check if active device (energy dependent)
  5. Apply classification rules 1-22
  6. For software, apply MDCG 2019-11 algorithm
  7. Document classification rationale
  8. Validation: Classification confirmed with Notified Body

Classification Matrix

| Factor | Class I | Class IIa | Class IIb | Class III |
|--------|---------|-----------|-----------|-----------|
| Duration | Any | Short-term | Long-term | Long-term |
| Invasiveness | Non-invasive | Body orifice | Surgical | Implantable |
| System | Any | Non-critical | Critical organs | CNS/cardiac |
| Risk | Lowest | Low-medium | Medium-high | Highest |

Software Classification (MDCG 2019-11)

| Information Use | Condition Severity | Class |
|-----------------|-------------------|-------|
| Informs decision | Non-serious | IIa |
| Informs decision | Serious | IIb |
| Drives/treats | Critical | III |

Classification Examples

Example 1: Absorbable Surgical Suture


  • Rule 8 (implantable, long-term)

  • Duration: > 30 days (absorbed)

  • Contact: General tissue

  • Classification: Class IIb

Example 2: AI Diagnostic Software


  • Rule 11 + MDCG 2019-11

  • Function: Diagnoses serious condition

  • Classification: Class IIb

Example 3: Cardiac Pacemaker


  • Rule 8 (implantable)

  • Contact: Central circulatory system

  • Classification: Class III

---

Technical Documentation

Prepare technical file per Annex II and III:

  1. Create device description (variants, accessories, intended purpose)
  2. Develop labeling (Article 13 requirements, IFU)
  3. Document design and manufacturing process
  4. Complete GSPR compliance matrix
  5. Prepare benefit-risk analysis
  6. Compile verification and validation evidence
  7. Integrate risk management file (ISO 14971)
  8. Validation: Technical file reviewed for completeness

Technical File Structure

ANNEX II TECHNICAL DOCUMENTATION
├── Device description and UDI-DI
├── Label and instructions for use
├── Design and manufacturing info
├── GSPR compliance matrix
├── Benefit-risk analysis
├── Verification and validation
└── Clinical evaluation report

GSPR Compliance Checklist

| Requirement | Evidence | Status |
|-------------|----------|--------|
| Safe design (GSPR 1-3) | Risk management file | ☐ |
| Chemical properties (GSPR 10.1) | Biocompatibility report | ☐ |
| Infection risk (GSPR 10.2) | Sterilization validation | ☐ |
| Software requirements (GSPR 17) | IEC 62304 documentation | ☐ |
| Labeling (GSPR 23) | Label artwork, IFU | ☐ |

Conformity Assessment Routes

| Class | Route | NB Involvement |
|-------|-------|----------------|
| I | Annex II self-declaration | None |
| Is/Im | Annex II + IX/XI | Sterile/measuring aspects |
| IIa | Annex II + IX or XI | Product or QMS |
| IIb | Annex IX + X or X + XI | Type exam + production |
| III | Annex IX + X | Full QMS + type exam |

---

Clinical Evidence

Develop clinical evidence strategy per Annex XIV:

  1. Define clinical claims and endpoints
  2. Conduct systematic literature search
  3. Appraise clinical data quality
  4. Assess equivalence (technical, biological, clinical)
  5. Identify evidence gaps
  6. Determine if clinical investigation required
  7. Prepare Clinical Evaluation Report (CER)
  8. Validation: CER reviewed by qualified evaluator

Evidence Requirements by Class

| Class | Minimum Evidence | Investigation |
|-------|------------------|---------------|
| I | Risk-benefit analysis | Not typically required |
| IIa | Literature + post-market | May be required |
| IIb | Systematic literature review | Often required |
| III | Comprehensive clinical data | Required (Article 61) |

Clinical Evaluation Report Structure

CER CONTENTS
├── Executive summary
├── Device scope and intended purpose
├── Clinical background (state of the art)
├── Literature search methodology
├── Data appraisal and analysis
├── Safety and performance conclusions
├── Benefit-risk determination
└── PMCF plan summary

Qualified Evaluator Requirements

  • Medical degree or equivalent healthcare qualification
  • 4+ years clinical experience in relevant field
  • Training in clinical evaluation methodology
  • Understanding of MDR requirements

---

Post-Market Surveillance

Establish PMS system per Chapter VII:

  1. Develop PMS plan (Article 84)
  2. Define data collection methods
  3. Establish complaint handling procedures
  4. Create vigilance reporting process
  5. Plan Periodic Safety Update Reports (PSUR)
  6. Integrate with PMCF activities
  7. Define trend analysis and signal detection
  8. Validation: PMS system audited annually

PMS System Components

| Component | Requirement | Frequency |
|-----------|-------------|-----------|
| PMS Plan | Article 84 | Maintain current |
| PSUR | Class IIa and higher | Per class schedule |
| PMCF Plan | Annex XIV Part B | Update with CER |
| PMCF Report | Annex XIV Part B | Annual (Class III) |
| Vigilance | Articles 87-92 | As events occur |

PSUR Schedule

| Class | Frequency |
|-------|-----------|
| Class III | Annual |
| Class IIb implantable | Annual |
| Class IIb | Every 2 years |
| Class IIa | When necessary |

Serious Incident Reporting

| Timeline | Requirement |
|----------|-------------|
| 2 days | Serious public health threat |
| 10 days | Death or serious deterioration |
| 15 days | Other serious incidents |

---

EUDAMED and UDI

Implement UDI system per Article 27:

  1. Obtain issuing entity code (GS1, HIBCC, ICCBBA)
  2. Assign UDI-DI to each device variant
  3. Assign UDI-PI (production identifier)
  4. Apply UDI carrier to labels (AIDC + HRI)
  5. Register actor in EUDAMED
  6. Register devices in EUDAMED
  7. Upload certificates when available
  8. Validation: UDI verified on sample labels

EUDAMED Modules

| Module | Content | Actor |
|--------|---------|-------|
| Actor | Company registration | Manufacturer, AR |
| UDI/Device | Device and variant data | Manufacturer |
| Certificates | NB certificates | Notified Body |
| Clinical Investigation | Study registration | Sponsor |
| Vigilance | Incident reports | Manufacturer |
| Market Surveillance | Authority actions | Competent Authority |

UDI Label Requirements

Required elements per Article 13:

  • [ ] UDI-DI (device identifier)
  • [ ] UDI-PI (production identifier) for Class II+
  • [ ] AIDC format (barcode/RFID)
  • [ ] HRI format (human-readable)
  • [ ] Manufacturer name and address
  • [ ] Lot/serial number
  • [ ] Expiration date (if applicable)

---

Reference Documentation

MDR Classification Guide

references/mdr-classification-guide.md contains:

  • Complete Annex VIII classification rules (Rules 1-22)
  • Software classification per MDCG 2019-11
  • Worked classification examples
  • Conformity assessment route selection

Clinical Evidence Requirements

references/clinical-evidence-requirements.md contains:

  • Clinical evidence framework and hierarchy
  • Literature search methodology
  • Clinical Evaluation Report structure
  • PMCF plan and evaluation report guidance

Technical Documentation Templates

references/technical-documentation-templates.md contains:

  • Annex II and III content requirements
  • Design History File structure
  • GSPR compliance matrix template
  • Declaration of Conformity template
  • Notified Body submission checklist

---

Tools

MDR Gap Analyzer

# Quick gap analysis
python scripts/mdr_gap_analyzer.py --device "Device Name" --class IIa

# JSON output for integration
python scripts/mdr_gap_analyzer.py --device "Device Name" --class III --output json

# Interactive assessment
python scripts/mdr_gap_analyzer.py --interactive

Analyzes device against MDR requirements, identifies compliance gaps, generates prioritized recommendations.

Output includes:


  • Requirements checklist by category

  • Gap identification with priorities

  • Critical gap highlighting

  • Compliance roadmap recommendations

---

Notified Body Interface

Selection Criteria

| Factor | Considerations |
|--------|----------------|
| Designation scope | Covers your device type |
| Capacity | Timeline for initial audit |
| Geographic reach | Markets you need to access |
| Technical expertise | Experience with your technology |
| Fee structure | Transparency, predictability |

Pre-Submission Checklist

  • [ ] Technical documentation complete
  • [ ] GSPR matrix fully addressed
  • [ ] Risk management file current
  • [ ] Clinical evaluation report complete
  • [ ] QMS (ISO 13485) certified
  • [ ] Labeling and IFU finalized
  • [ ] Validation: Internal gap assessment complete

SKILL.md source

---
name: mdr-745-specialist
description: EU MDR 2017/745 compliance specialist for medical device classification, technical documentation, clinical evidence, and post-market surveillance. Covers Annex VIII classification rules, Annex II/I...
---

# MDR 2017/745 Specialist

EU MDR compliance patterns for medical device classification, technical documentation, and clinical evidence.

---

## Table of Contents

- [Device Classification Workflow](#device-classification-workflow)
- [Technical Documentation](#technical-documentation)
- [Clinical Evidence](#clinical-evidence)
- [Post-Market Surveillance](#post-market-surveillance)
- [EUDAMED and UDI](#eudamed-and-udi)
- [Reference Documentation](#reference-documentation)
- [Tools](#tools)

---

## Device Classification Workflow

Classify device under MDR Annex VIII:

1. Identify device duration (transient, short-term, long-term)
2. Determine invasiveness level (non-invasive, body orifice, surgical)
3. Assess body system contact (CNS, cardiac, other)
4. Check if active device (energy dependent)
5. Apply classification rules 1-22
6. For software, apply MDCG 2019-11 algorithm
7. Document classification rationale
8. **Validation:** Classification confirmed with Notified Body

### Classification Matrix

| Factor | Class I | Class IIa | Class IIb | Class III |
|--------|---------|-----------|-----------|-----------|
| Duration | Any | Short-term | Long-term | Long-term |
| Invasiveness | Non-invasive | Body orifice | Surgical | Implantable |
| System | Any | Non-critical | Critical organs | CNS/cardiac |
| Risk | Lowest | Low-medium | Medium-high | Highest |

### Software Classification (MDCG 2019-11)

| Information Use | Condition Severity | Class |
|-----------------|-------------------|-------|
| Informs decision | Non-serious | IIa |
| Informs decision | Serious | IIb |
| Drives/treats | Critical | III |

### Classification Examples

**Example 1: Absorbable Surgical Suture**
- Rule 8 (implantable, long-term)
- Duration: > 30 days (absorbed)
- Contact: General tissue
- Classification: **Class IIb**

**Example 2: AI Diagnostic Software**
- Rule 11 + MDCG 2019-11
- Function: Diagnoses serious condition
- Classification: **Class IIb**

**Example 3: Cardiac Pacemaker**
- Rule 8 (implantable)
- Contact: Central circulatory system
- Classification: **Class III**

---

## Technical Documentation

Prepare technical file per Annex II and III:

1. Create device description (variants, accessories, intended purpose)
2. Develop labeling (Article 13 requirements, IFU)
3. Document design and manufacturing process
4. Complete GSPR compliance matrix
5. Prepare benefit-risk analysis
6. Compile verification and validation evidence
7. Integrate risk management file (ISO 14971)
8. **Validation:** Technical file reviewed for completeness

### Technical File Structure

```
ANNEX II TECHNICAL DOCUMENTATION
├── Device description and UDI-DI
├── Label and instructions for use
├── Design and manufacturing info
├── GSPR compliance matrix
├── Benefit-risk analysis
├── Verification and validation
└── Clinical evaluation report
```

### GSPR Compliance Checklist

| Requirement | Evidence | Status |
|-------------|----------|--------|
| Safe design (GSPR 1-3) | Risk management file | ☐ |
| Chemical properties (GSPR 10.1) | Biocompatibility report | ☐ |
| Infection risk (GSPR 10.2) | Sterilization validation | ☐ |
| Software requirements (GSPR 17) | IEC 62304 documentation | ☐ |
| Labeling (GSPR 23) | Label artwork, IFU | ☐ |

### Conformity Assessment Routes

| Class | Route | NB Involvement |
|-------|-------|----------------|
| I | Annex II self-declaration | None |
| Is/Im | Annex II + IX/XI | Sterile/measuring aspects |
| IIa | Annex II + IX or XI | Product or QMS |
| IIb | Annex IX + X or X + XI | Type exam + production |
| III | Annex IX + X | Full QMS + type exam |

---

## Clinical Evidence

Develop clinical evidence strategy per Annex XIV:

1. Define clinical claims and endpoints
2. Conduct systematic literature search
3. Appraise clinical data quality
4. Assess equivalence (technical, biological, clinical)
5. Identify evidence gaps
6. Determine if clinical investigation required
7. Prepare Clinical Evaluation Report (CER)
8. **Validation:** CER reviewed by qualified evaluator

### Evidence Requirements by Class

| Class | Minimum Evidence | Investigation |
|-------|------------------|---------------|
| I | Risk-benefit analysis | Not typically required |
| IIa | Literature + post-market | May be required |
| IIb | Systematic literature review | Often required |
| III | Comprehensive clinical data | Required (Article 61) |

### Clinical Evaluation Report Structure

```
CER CONTENTS
├── Executive summary
├── Device scope and intended purpose
├── Clinical background (state of the art)
├── Literature search methodology
├── Data appraisal and analysis
├── Safety and performance conclusions
├── Benefit-risk determination
└── PMCF plan summary
```

### Qualified Evaluator Requirements

- Medical degree or equivalent healthcare qualification
- 4+ years clinical experience in relevant field
- Training in clinical evaluation methodology
- Understanding of MDR requirements

---

## Post-Market Surveillance

Establish PMS system per Chapter VII:

1. Develop PMS plan (Article 84)
2. Define data collection methods
3. Establish complaint handling procedures
4. Create vigilance reporting process
5. Plan Periodic Safety Update Reports (PSUR)
6. Integrate with PMCF activities
7. Define trend analysis and signal detection
8. **Validation:** PMS system audited annually

### PMS System Components

| Component | Requirement | Frequency |
|-----------|-------------|-----------|
| PMS Plan | Article 84 | Maintain current |
| PSUR | Class IIa and higher | Per class schedule |
| PMCF Plan | Annex XIV Part B | Update with CER |
| PMCF Report | Annex XIV Part B | Annual (Class III) |
| Vigilance | Articles 87-92 | As events occur |

### PSUR Schedule

| Class | Frequency |
|-------|-----------|
| Class III | Annual |
| Class IIb implantable | Annual |
| Class IIb | Every 2 years |
| Class IIa | When necessary |

### Serious Incident Reporting

| Timeline | Requirement |
|----------|-------------|
| 2 days | Serious public health threat |
| 10 days | Death or serious deterioration |
| 15 days | Other serious incidents |

---

## EUDAMED and UDI

Implement UDI system per Article 27:

1. Obtain issuing entity code (GS1, HIBCC, ICCBBA)
2. Assign UDI-DI to each device variant
3. Assign UDI-PI (production identifier)
4. Apply UDI carrier to labels (AIDC + HRI)
5. Register actor in EUDAMED
6. Register devices in EUDAMED
7. Upload certificates when available
8. **Validation:** UDI verified on sample labels

### EUDAMED Modules

| Module | Content | Actor |
|--------|---------|-------|
| Actor | Company registration | Manufacturer, AR |
| UDI/Device | Device and variant data | Manufacturer |
| Certificates | NB certificates | Notified Body |
| Clinical Investigation | Study registration | Sponsor |
| Vigilance | Incident reports | Manufacturer |
| Market Surveillance | Authority actions | Competent Authority |

### UDI Label Requirements

Required elements per Article 13:

- [ ] UDI-DI (device identifier)
- [ ] UDI-PI (production identifier) for Class II+
- [ ] AIDC format (barcode/RFID)
- [ ] HRI format (human-readable)
- [ ] Manufacturer name and address
- [ ] Lot/serial number
- [ ] Expiration date (if applicable)

---

## Reference Documentation

### MDR Classification Guide

`references/mdr-classification-guide.md` contains:

- Complete Annex VIII classification rules (Rules 1-22)
- Software classification per MDCG 2019-11
- Worked classification examples
- Conformity assessment route selection

### Clinical Evidence Requirements

`references/clinical-evidence-requirements.md` contains:

- Clinical evidence framework and hierarchy
- Literature search methodology
- Clinical Evaluation Report structure
- PMCF plan and evaluation report guidance

### Technical Documentation Templates

`references/technical-documentation-templates.md` contains:

- Annex II and III content requirements
- Design History File structure
- GSPR compliance matrix template
- Declaration of Conformity template
- Notified Body submission checklist

---

## Tools

### MDR Gap Analyzer

```bash
# Quick gap analysis
python scripts/mdr_gap_analyzer.py --device "Device Name" --class IIa

# JSON output for integration
python scripts/mdr_gap_analyzer.py --device "Device Name" --class III --output json

# Interactive assessment
python scripts/mdr_gap_analyzer.py --interactive
```

Analyzes device against MDR requirements, identifies compliance gaps, generates prioritized recommendations.

**Output includes:**
- Requirements checklist by category
- Gap identification with priorities
- Critical gap highlighting
- Compliance roadmap recommendations

---

## Notified Body Interface

### Selection Criteria

| Factor | Considerations |
|--------|----------------|
| Designation scope | Covers your device type |
| Capacity | Timeline for initial audit |
| Geographic reach | Markets you need to access |
| Technical expertise | Experience with your technology |
| Fee structure | Transparency, predictability |

### Pre-Submission Checklist

- [ ] Technical documentation complete
- [ ] GSPR matrix fully addressed
- [ ] Risk management file current
- [ ] Clinical evaluation report complete
- [ ] QMS (ISO 13485) certified
- [ ] Labeling and IFU finalized
- [ ] **Validation:** Internal gap assessment complete

Related skills 6

agent-browser

★ Featured Official

Browser automation CLI for AI agents. Use when the user needs to interact with websites, including navigating pages, filling forms, clicking buttons, taking screenshots, extracting data, testing web apps, or automating any browser task. Triggers include requests to "open a website", "fill out a form", "click a button", "take a screenshot", "scrape data from a page", "test this web app", "login to a site", "automate browser actions", or any task requiring programmatic web interaction. Also use...

vercel-labs 297k
Testing & Quality

grill-me

★ Featured

Interview the user relentlessly about a plan or design until reaching shared understanding, resolving each branch of the decision tree. Use when user wants to stress-test a plan, get grilled on their design, or mentions "grill me".

mattpocock 192k
Testing & Quality

grill-with-docs

★ Featured

Grilling session that challenges your plan against the existing domain model, sharpens terminology, and updates documentation (CONTEXT.md, ADRs) inline as decisions crystallise. Use when user wants to stress-test a plan against their project's language and documented decisions.

mattpocock 138k
Testing & Quality

minimal-run-and-audit

★ Featured

RigorPilot trusted execution and reporting skill for README-first deep learning repo reproduction. Use when the task is specifically to capture or normalize evidence from the selected smoke test or documented inference or evaluation command and write standardized `repro_outputs/` files, including patch notes when repository files changed. Do not use for training execution, initial repo intake, generic environment setup, paper lookup, target selection, hidden scientific-meaning changes, or end...

lllllllama 127k
Testing & Quality

polish

★ Featured

Performs a final quality pass fixing alignment, spacing, consistency, and micro-detail issues before shipping. Use when the user mentions polish, finishing touches, pre-launch review, something looks off, or wants to go from good to great.

pbakaus 86k
Testing & Quality

critique

★ Featured

Evaluate design from a UX perspective, assessing visual hierarchy, information architecture, emotional resonance, cognitive load, and overall quality with quantitative scoring, persona-based testing, automated anti-pattern detection, and actionable feedback. Use when the user asks to review, critique, evaluate, or give feedback on a design or component.

pbakaus 83k
Testing & Quality